MKLabExplore all apps →

Energy / synthetic browser explorer

Solmora Grid

Compare precomputed synthetic solar, storage, grid and backup scenarios and inspect hourly energy dispatch.

Open the explorer ↗Read the limits

No sign-in · Precomputed synthetic results · Source repository private

Actual Solmora Grid browser explorer with explicitly synthetic example results
Actual hosted browser edition with synthetic sample data.

What you can try

  • Choose a synthetic planning scenario and design candidate.
  • Inspect the dispatch balance and assumption-dependent economics.
  • Compare the bounded candidates and export the displayed result.

Start in three steps

  1. Open the explorer and read its data/provenance note.
  2. Choose a sample and inspect a chart and its hourly table.
  3. Export the displayed result with the assumptions attached.

Keep the boundary clear

The browser explores precomputed results from the private Python simulation. It does not certify system sizing, predict measured site output, operate equipment or run paid Astra reviews.

These are synthetic analytical examples, not site measurements, validated operational forecasts, installation designs or investment advice. Local numerical results are distinct from any optional provider narrative.

Public edition and private source

The website shares a bounded analytical workflow. The Python application and its account, persistence and job services remain in a private GitHub repository. Public visitors are invited to share this demo URL with its limits attached.

App facts · Plain-text overview · Notices

MATHEMATICAL SPECIFICATION & UNITS

Governing Equations, Inputs, Outputs & Dimensional Conventions

The equations below describe model assumptions. Consult the app metadata for the published edition; these equations alone do not demonstrate runtime execution or validation:

E_load(t) = E_PV→load(t) + E_batt_dis(t) + E_grid(t) + E_gen(t); E_stored(t+1) = E_stored(t) + η_ch E_charge_in(t) − E_discharge_out(t)/η_dis; soc_next = soc + (η_ch E_charge_in − E_discharge_out / η_dis) / C_usable; Max Balance Error (kWh) = max_t |Supply(t) − Demand(t)|; acceptance requires stated tolerances and tested fixtures

Declared Units & Arithmetic Conventions: Annual simulation over 8,760 hours (chart displays first 96 hours: Jan 1–4 UTC); stored energy E_stored and usable capacity C_usable in kWh; fractional state of charge soc in [0, 1] (dimensionless); charge/discharge efficiencies η_ch, η_dis in (0, 1]; peak load in kW; CO2 emissions in kg CO2; reliability in fraction of load served (0–1).

Scope & Operational Boundary: Precomputed solar, storage, grid and backup design candidates with dispatch/economic comparisons. Synthetic assumptions; not certified sizing, live control or guaranteed savings.

Launch Interactive Solmora Grid Runtime → · Read Full Methodology & Validation Notes → · Download JSON Dataset (run/data/demo.json)

REPRODUCIBLE WORKED EXAMPLE & BENCHMARK TABLE

Illustrative Worked Example & Reference Table

Illustrative Worked Example: Commercial Scenario (Annual load = 480,000 kWh across 8,760 hours, peak load = 110.49 kW): The grid-only baseline imports 480,000 kWh with 192,000 kg CO2 emissions and 0.0 kWh energy-balance error. Comparing solar + storage design candidates quantifies renewable fraction, battery equivalent cycles, curtailment, and discounted lifecycle cost.

Reproducible benchmark scenarios shipped in the Solmora Grid browser edition (Synthetic / Precomputed Evidence)
Candidate DesignSimulation HoursAnnual Load (kWh)Peak Load (kW)Grid Import (kWh)CO2 Emissions (kg)Balance Error (kWh)
Baseline (Grid Only)8,760 h480,000110.49480,000192,0000.000
Solar + BESS Candidate8,760 h480,000110.49Reduced via PV+BESSLowered proportionally0.000
Resilience / Off-Grid8,760 hBounded LoadNot reportedDispatch PrioritizedFuel + Grid Tracked0.000
PROCEDURAL USAGE GUIDE

How to Use Solmora Grid in 3 Reproducible Steps

  1. Select a Baseline Scenario or Practice Module: Open the interactive browser runtime and choose one of the shipped synthetic presets or diagnostic modules to load its documented input parameters and unit declarations.
  2. Inspect Intermediate Traces & Constraints: Review the computed ledger, error diagnostics (MAE/RMSE/margin/balance checks), or bilingual explanations alongside the governing equations documented on mkcore.co.technology/methodology/.
  3. Export Portable Evidence (JSON / CSV): Export your scenario results, assumptions, or local study plan as a self-contained JSON or CSV file for offline verification and local re-import.
FREQUENTLY ASKED QUESTIONS

Methodological & Boundary FAQs

What mathematical model and units does Solmora Grid use?

Solmora Grid applies E_load(t) = E_PV→load(t) + E_batt_dis(t) + E_grid(t) + E_gen(t); E_stored(t+1) = E_stored(t) + η_ch E_charge_in(t) − E_discharge_out(t)/η_dis; soc_next = soc + (η_ch E_charge_in − E_discharge_out / η_dis) / C_usable; Max Balance Error (kWh) = max_t |Supply(t) − Demand(t)|; acceptance requires stated tolerances and tested fixtures. Units: Annual simulation over 8,760 hours (chart displays first 96 hours: Jan 1–4 UTC); stored energy E_stored and usable capacity C_usable in kWh; fractional state of charge soc in [0, 1] (dimensionless); charge/discharge efficiencies η_ch, η_dis in (0, 1]; peak load in kW; CO2 emissions in kg CO2; reliability in fraction of load served (0–1).

What are the operational boundaries and limitations of Solmora Grid?

Precomputed solar, storage, grid and backup design candidates with dispatch/economic comparisons. Synthetic assumptions; not certified sizing, live control or guaranteed savings. The public edition uses synthetic or precomputed demonstration fixtures; executable capabilities require separate verification.

How can I reproduce the benchmark results in Solmora Grid?

Open the interactive browser workspace at ./run/, select Case 1 to inspect the worked result (Commercial Scenario (Annual load = 480,000 kWh across 8,760 hours, peak load = 110.49 kW): The grid-only baseline imports 480,000 kWh with 192,000 kg CO2 emissions and 0.0 kWh energy-balance error. Comparing solar + storage design candidates quantifies renewable fraction, battery equivalent cycles, curtailment, and discounted lifecycle cost.), and export the JSON or CSV evidence ledger.

PROVENANCE, ATTRIBUTION & RESEARCH ECOSYSTEM

Engineering Attribution & Interconnected Research Hub

Authored and maintained by (Aalborg University · BESS QA/QC & Power Systems Specialist). Canonical URL: https://mkcore.co.technology/solar-storage/ · Source revision: not-recorded · Runtime SHA-256 prefix: not-recorded · Repository provenance: https://github.com/mohammadrezwankhan/solmora-grid (private source engine; public deterministic browser projection).

Application Metadata (app.json) · Build Provenance (provenance.json) · AI / LLM Discovery Guide (llms.txt) · Full Technical Corpus (llms-full.txt) · Semantic Knowledge Graph (knowledge-graph.jsonld)

Explore the MKLab & ASTRA Research Ecosystem